Hammerlindl method for gas in place
Input(s)
\(\mathrm{G}_{\mathrm{app}}\): Apparent Gas in Place (SCF)
R: Ratio of the effective Total System Compressibility to gas Compressibility (dimensionless)
Output(s)
G: Gas in Place (SCF)
Formula(s)
\[
\mathrm{G}=\frac{\mathrm{G}_{\mathrm{app}}}{\mathrm{R}}
\]
Reference(s)
Ahmed, T., McKinney, P.D. 2005. Advanced Reservoir Engineering, Gulf Publishing of Elsevier, Chapter: 3, Page: 216 .