Estimating recovery steam drive (volume of steam in reservoir)

Input(s)

\(Q_{i}\): Heat Injection Rate \((\mathrm{BTU} / \mathrm{d})\)

\(\mathrm{t}\): Injection Time \((\mathrm{d})\)

\(E_{h s}\): Thermal Efficiency of Steam Zone (dimensionless)

\(T_{i}\): Injection Temperature \(\left({ }^{\circ} \mathrm{F}\right)\)

\(T_{a}\): Ambient Temperature \(\left({ }^{\circ} \mathrm{F}\right)\)

Output(s)

\(V_{s}\): Gross Volume of Steam in Reservoir (ac ft)

Formula(s)

\[ \mathrm{V}_{\mathrm{s}}=\frac{\mathrm{Q}_{\mathrm{i}} * \mathrm{t} * \mathrm{E}_{\mathrm{hs}}}{38.1 * 43560 *\left(\mathrm{~T}_{\mathrm{i}}-\mathrm{T}_{\mathrm{a}}\right)} \]

Reference(s)

Pratts, M. (1986). Thermal Recovery Monograph Vol. 7. Society of Petroleum Engineers, Houston, Page: 76.